Resistance exercise training reduces arterial reservoir pressure in older adults with prehypertension and hypertension KS Heffernan, ES Yoon, JE Sharman, JE Davies, YT Shih, CH Chen, ... Hypertension Research 36 (5), 422-427, 2013 | 172 | 2013 |
Quantification of the calibration error in the transfer function-derived central aortic blood pressures YT Shih, HM Cheng, SH Sung, WC Hu, CH Chen American journal of hypertension 24 (12), 1312-1317, 2011 | 88 | 2011 |
Quantitative analysis of intrinsic skin aging in dermal papillae by in vivo harmonic generation microscopy YH Liao, WC Kuo, SY Chou, CS Tsai, GL Lin, MR Tsai, YT Shih, GG Lee, ... Biomedical optics express 5 (9), 3266-3279, 2014 | 63 | 2014 |
Measurement Accuracy of a Stand-Alone Oscillometric Central Blood Pressure Monitor: A Validation Report for Microlife WatchBP Office Central<? Typesetter please check … HM Cheng, SH Sung, YT Shih, SY Chuang, WC Yu, CH Chen American journal of hypertension 26 (1), 42-50, 2013 | 46 | 2013 |
Prognostic significance of mechanical biomarkers derived from pulse wave analysis for predicting long-term cardiovascular mortality in two population-based cohorts HM Cheng, SY Chuang, JJ Wang, YT Shih, HN Wang, CJ Huang, ... International journal of cardiology 215, 388-395, 2016 | 45 | 2016 |
Application of the N-point moving average method for brachial pressure waveform–derived estimation of central aortic systolic pressure YT Shih, HM Cheng, SH Sung, WC Hu, CH Chen Hypertension 63 (4), 865-870, 2014 | 36 | 2014 |
Measurement of central aortic pulse pressure: noninvasive brachial cuff-based estimation by a transfer function vs. a novel pulse wave analysis method HM Cheng, SH Sung, YT Shih, SY Chuang, WC Yu, CH Chen American journal of hypertension 25 (11), 1162-1169, 2012 | 34 | 2012 |
Comparison of two generalized transfer functions for measuring central systolic blood pressure by an oscillometric blood pressure monitor YT Shih, HM Cheng, SH Sung, WC Hu, CH Chen Journal of Human Hypertension 27 (3), 204-210, 2013 | 32 | 2013 |
Single-channel impedance plethysmography neck patch device for unobtrusive wearable cardiovascular monitoring TW Wang, HW Chu, WX Chen, YT Shih, PC Hsu, HM Cheng, SF Lin IEEE Access 8, 184909-184919, 2020 | 24 | 2020 |
Near-field sub-THz transmission-type image system for vessel imaging in-vivo TF Tseng, SC Yang, YT Shih, YF Tsai, TD Wang, CK Sun Optics Express 23 (19), 25058-25071, 2015 | 24 | 2015 |
Measurement of central systolic blood pressure by pulse volume plethysmography with a noninvasive blood pressure monitor SH Sung, HM Cheng, SY Chuang, YT Shih, KL Wang, YH Chen, SJ Lin, ... American journal of hypertension 25 (5), 542-548, 2012 | 20 | 2012 |
In vivo third-harmonic generation microscopy study on vitiligo patients YH Liao, YH Su, YT Shih, WS Chen, SH Jee, CK Sun Journal of Biomedical Optics 25 (1), 014504-014504, 2020 | 18 | 2020 |
Bio-impedance measurement optimization for high-resolution carotid pulse sensing TW Wang, HW Chu, L Chou, YL Sung, YT Shih, PC Hsu, HM Cheng, ... Sensors 21 (5), 1600, 2021 | 17 | 2021 |
Blood pressure monitor and method for calculating blood pressure thereof HU Wei-Chih, LY Shyu, YT Shih, YJ Sun, CH Chen, HM Cheng US Patent App. 12/716,487, 2011 | 14 | 2011 |
Is noninvasive brachial systolic blood pressure an accurate estimate of central aortic systolic blood pressure? YT Shih, HM Cheng, SH Sung, SY Chuang, WC Hu, CH Chen American Journal of Hypertension 29 (11), 1283-1291, 2016 | 12 | 2016 |
Virtual spatial overlap modulation microscopy for resolution improvement WC Kuo, YT Shih, HC Hsu, YH Cheng, YH Liao, CK Sun Optics Express 21 (24), 30007-30018, 2013 | 11 | 2013 |
Classification of established atopic dermatitis in children with the in vivo imaging methods JH Lee, YT Shih, ML Wei, CK Sun, BL Chiang Journal of Biophotonics 12 (5), e201800148, 2019 | 8 | 2019 |
A study on applying slide-free label-free harmonic generation microscopy for noninvasive assessment of melasma treatments with histopathological parameters ML Wei, YH Liao, WH Weng, YT Shih, YS Sheen, CK Sun IEEE Journal of Selected Topics in Quantum Electronics 27 (4), 1-10, 2021 | 5 | 2021 |
Evaluation of blood pressure pulse wave velocity and arterial relaxation constant WC Hu, JJ Wang, LY Shyu, HM Cheng, CH Chen, YT Shih, YJ Sun 2009 36th Annual Computers in Cardiology Conference (CinC), 745-748, 2009 | 3 | 2009 |
Method for detecting vascular sclerosis HU Wei-Chih, LY Shyu, YT Shih, YJ Sun, CH Chen, HM Cheng US Patent 9,022,943, 2015 | 1 | 2015 |