Holographic glucose sensors S Kabilan, AJ Marshall, FK Sartain, MC Lee, A Hussain, X Yang, J Blyth, ... Biosensors and Bioelectronics 20 (8), 1602-1610, 2005 | 203 | 2005 |
Glucose-sensitive holographic sensors for monitoring bacterial growth MC Lee, S Kabilan, A Hussain, X Yang, J Blyth, CR Lowe Analytical chemistry 76 (19), 5748-5755, 2004 | 199 | 2004 |
pH-sensitive holographic sensors AJ Marshall, J Blyth, CAB Davidson, CR Lowe Analytical Chemistry 75 (17), 4423-4431, 2003 | 195 | 2003 |
Light-directed writing of chemically tunable narrow-band holographic sensors AK Yetisen, H Butt, F da Cruz Vasconcellos, Y Montelongo, ... Wiley, 2014 | 132 | 2014 |
Towards the real-time monitoring of glucose in tear fluid: Holographic glucose sensors with reduced interference from lactate and pH X Yang, X Pan, J Blyth, CR Lowe Biosensors and Bioelectronics 23 (6), 899-905, 2008 | 124 | 2008 |
Glucose‐sensitive holographic sensors S Kabilan, J Blyth, MC Lee, AJ Marshall, A Hussain, XP Yang, CR Lowe Journal of Molecular Recognition 17 (3), 162-166, 2004 | 107 | 2004 |
Metal ion-sensitive holographic sensors AG Mayes, J Blyth, RB Millington, CR Lowe Analytical chemistry 74 (15), 3649-3657, 2002 | 105 | 2002 |
A holographic alcohol sensor AG Mayes, J Blyth, M Kyröläinen-Reay, RB Millington, CR Lowe Analytical Chemistry 71 (16), 3390-3396, 1999 | 90 | 1999 |
Holographic sensor for water in solvents J Blyth, RB Millington, AG Mayes, ER Frears, CR Lowe Analytical chemistry 68 (7), 1089-1094, 1996 | 80 | 1996 |
A holographic sensor for proteases RB Millington, AG Mayes, J Blyth, CR Lowe Analytical Chemistry 67 (23), 4229-4233, 1995 | 71 | 1995 |
Printable surface holograms via laser ablation FC Vasconcellos, AK Yetisen, Y Montelongo, H Butt, A Grigore, ... Acs Photonics 1 (6), 489-495, 2014 | 67 | 2014 |
Metabolite-sensitive holographic biosensors AJ Marshall, DS Young, J Blyth, S Kabilan, CR Lowe Analytical Chemistry 76 (5), 1518-1523, 2004 | 67 | 2004 |
Methylene blue sensitized dichromated gelatin holograms: a new electron donor for their improved photosensitivity J Blyth Applied optics 30 (13), 1598-1602, 1991 | 66 | 1991 |
Holographic detection of hydrocarbon gases and other volatile organic compounds JL Martinez-Hurtado, CAB Davidson, J Blyth, CR Lowe Langmuir 26 (19), 15694-15699, 2010 | 64 | 2010 |
Divalent metal ion-sensitive holographic sensors BM González, G Christie, CAB Davidson, J Blyth, CR Lowe Analytica chimica acta 528 (2), 219-228, 2005 | 56 | 2005 |
Covalent coupling of immunoglobulin G to a poly (vinyl) alcohol-poly (acrylic acid) graft polymer as a method for fabricating the interfacial-recognition layer of a surface … DM Disley, J Blyth, DC Cullen, HX You, S Eapen, CR Lowe Biosensors and Bioelectronics 13 (3-4), 383-396, 1998 | 46 | 1998 |
A diffusion method for making silver bromide based holographic recording material J Blyth, RB Millington, AG Mayes, CR Lowe The Imaging Science Journal 47 (2), 87-91, 1999 | 44 | 1999 |
A hologram biosensor for proteases RB Millington, AG Mayes, J Blyth, CR Lowe Sensors and Actuators B: Chemical 33 (1-3), 55-59, 1996 | 43 | 1996 |
Holographic sensors for the detection of bacterial spores D Bhatta, G Christie, B Madrigal-González, J Blyth, CR Lowe Biosensors and Bioelectronics 23 (4), 520-527, 2007 | 42 | 2007 |
Holographic sensors for the determination of ionic strength AJ Marshall, DS Young, S Kabilan, A Hussain, J Blyth, CR Lowe Analytica chimica acta 527 (1), 13-20, 2004 | 42 | 2004 |