The influence of uncemented femoral stem length and design on its primary stability: a finite element analysis M Reimeringer, N Nuño, C Desmarais-Trépanier, M Lavigne, ... Computer methods in biomechanics and biomedical engineering 16 (11), 1221-1231, 2013 | 98 | 2013 |
P4LM: A methodology for product lifecycle management F Danesi, N Gardan, Y Gardan, M Reimeringer Computers in industry 59 (2-3), 304-317, 2008 | 66 | 2008 |
The influence of contact ratio and its location on the primary stability of cementless total hip arthroplasty: A finite element analysis M Reimeringer, N Nuño Journal of biomechanics 49 (7), 1064-1070, 2016 | 29 | 2016 |
Effect of femoral mechanical properties on primary stability of cementless total hip arthroplasty: a finite element analysis M Reimeringer, N Nuño Advances in Biomechanics and Applications 1 (3), 187-210, 2014 | 8 | 2014 |
First operational systems based on the DIJA project Y Gardan, E Perrin, F Danesi, L Denis, N Gardan, F Heschung, E Malik, ... IASTED international conference on applied modelling and simulation (AMS …, 2002 | 7 | 2002 |
On the two-dimensional simplification of three-dimensional cementless hip stem numerical models FJ Quevedo González, M Reimeringer, N Nuño Journal of Biomechanical Engineering 139 (3), 031011, 2017 | 6 | 2017 |
Conception assistée de systèmes de remplissage en fonderie sur l'internet N GARDAN, M REIMERINGER Revue internationale de CFAO et d'informatique graphique 17 (1-2), 173-186, 2002 | 5 | 2002 |
CADFORSIM: Rules to improve the mesh quality M Reimeringer, N Gardan, Y Gardan, H Ugur Proceedings of the TMCE, 21-25, 2008 | 3 | 2008 |
CADFORSIM: Methodology and tools to integrate CAD and simulation M Reimeringer, N Gardan, F Danesi, Y Gardan Proceedings of the International Conference on Product Lifecycle Management …, 2007 | 3 | 2007 |
Evaluation of the Micromotion as a Function of the Area Where Press-Fit Is Applied for a Cementless Hip Implant M Reimeringer, N Nuno The Bone & Joint Journal 95-B, 158, 2013 | 1 | 2013 |
ASSESSMENT OF RANGE OF MOTION LOSS FOLLOWING LUMBAR INTERBODY FUSION ON A L4-L5 FINITE ELEMENT MODEL USING SOLID AND POROUS CAGES ND Tran, N Nuño, M Reimeringer Orthopaedic Proceedings 102 (SUPP_1), 115-115, 2020 | | 2020 |
Atypical femur fractures: influence of the femoral neck shaft angle and lateral bowing on maximum principal strains within the femur M Reimeringer, N Nuño, S Morin Journal of Bone and Mineral Research 33 (Suppl. 1), S187, 2018 | | 2018 |
On the 2D simplification of 3D cementless hip stem numerical models M Reimeringer, FQ Gonzalez, N Nuño Orthopaedic Proceedings 99 (SUPP_5), 106-106, 2017 | | 2017 |
Difference in the micromotion predicted by finite element analysis when press-fit and contact or press-fit and gap is achieved after surgery M Reimeringer, N Nuño Orthopaedic Proceedings 98 (SUPP_9), 148-148, 2016 | | 2016 |
OPTIMISATION OF A FUNCTIONALLY GRADED HIP STEM MADE OF POROUS METALLIC MATERIAL FQ Gonzalez, M Reimeringer, N Nuno Orthopaedic Proceedings 98 (SUPP_3), 136-136, 2016 | | 2016 |
OPTIMISATION OF THE VEPTR DESIGN TO AVOID COMPLICATIONS M Reimeringer, N Nuno, J Ouellet Orthopaedic Proceedings 98 (SUPP_3), 134-134, 2016 | | 2016 |
Difference in micromotion predicted by static and dynamic load cases M Reimeringer, N Nuno Orthopaedic Proceedings 98 (SUPP_3), 135-135, 2016 | | 2016 |
Atypical femur fractures: evaluation of femoral stresses and strain using finite element analysis T Kesteloot, SN Morin, M Reimeringer, E Belzile, JA de Guise, JP Brown, ... | | 2015 |
Effect of contact ratio on the primary stability of a cementless total hip arthroplasty M Reimeringer, N Nuño | | 2015 |
Optimization of a functionally graded hip stem made of porous metallic material F Quevedo-Gonzalez, M Reimeringer, N Nuño | | 2014 |