Total body water measurement by a modification of the bioimpedance spectroscopy method MY Jaffrin, M Fenech, MV Moreno, R Kieffer Medical and Biological Engineering and Computing 44, 873-882, 2006 | 67 | 2006 |
Assessment of body composition in adolescent subjects with anorexia nervosa by bioimpedance MV Moreno, DD Djeddi, MY Jaffrin Medical engineering & physics 30 (6), 783-791, 2008 | 47 | 2008 |
Evaluation of a foot-to-foot impedance meter measuring extracellular fluid volume in addition to fat-free mass and fat tissue mass MY Jaffrin, R Kieffer, MV Moreno Nutrition 21 (7-8), 815-824, 2005 | 43 | 2005 |
Evaluation on phantoms of the feasibility of a smart bra to detect breast cancer in young adults MV Moreno, E Herrera Sensors 19 (24), 5491, 2019 | 23 | 2019 |
Measurements of total body water with a foot-to-foot impedancemeter MY Jaffrin, MV Moreno Medical engineering & physics 30 (4), 483-489, 2008 | 17 | 2008 |
Etude de la composition corporelle par impédancemétrie sur des adultes et des enfants sains et pathologiques MV Moreno Université de Technologie de Compiègne, 2007 | 17 | 2007 |
Bioimpedance data monitoring in physical preparation: a real interest for performance of elite skiers for Winter Olympic Games 2010 J Rebeyrol, MV Moreno, E Ribbe, L Buttafoghi, O Pédron, C Dechavanne Procedia Engineering 2 (2), 2881-2887, 2010 | 11 | 2010 |
Case study: using monitoring of body composition data obtained by bioimpedance, in training of an elite male runner J Rebeyrol, MV Moreno, E Ribbe, A Vannicatte Procedia Engineering 2 (2), 3059-3064, 2010 | 11 | 2010 |
Evaluation of a multifrequency impedancemeter by biphotonic densitometry, measuring independent tissue indices, in supine and standing position. Comparison with skin folds MV Moreno, E Ribbe, J Rebeyrol, A Vannicatte, L Krief Gazz Med Ital Arch Sci Med 174, 1-2, 2015 | 7 | 2015 |
Evaluation of a new impedancemeter to independently measure extracellular, intracellular and total body water volumes: application to the measurement of hydration MV Moreno, E Ribbe-Cornet, J Rebeyrol, A Vannicatte, L Krief Medical & biological engineering & computing 53, 989-999, 2015 | 6 | 2015 |
New reusable elastomer electrodes for assessing body composition MV Moreno, L Chaset, PA Bittner, C Barthod, M Passard Journal of Physics: Conference Series 434 (1), 012026, 2013 | 6 | 2013 |
Evaluation of a new impedancemeter to independently access extracellular, intracellular and total body water volumes Application to the measurement of hydration MV Moreno, E Ribbe, J Rebeyrol, A Vannicatte, L Krief review, 2015 | 5 | 2015 |
Conception of a phantom in agar-agar gel with the same bio-impedance properties as human quadriceps M Peixoto, MV Moreno, N Khider Sensors 21 (15), 5195, 2021 | 4 | 2021 |
Ocular Phantom-Based Feasibility Study of an Early Diagnosis Device for Glaucoma MV Moreno, C Houriet, PA Grounauer Sensors 21 (2), 579, 2021 | 4 | 2021 |
Bio-impedance body composition comparisons between athletes and healthy subjects A Clarion, E Ribbe, J Rebeyrol, MP Rousseaux-Rousseaux-Blanchi, ... Journal of Physics: Conference Series 434 (1), 012064, 2013 | 3 | 2013 |
Analyse segmentaire de la composition corporelle par bioimpédance E Ribbe, MN Coux, MV Moreno Intelligent Health & Preventive Medicine International Symposium, 2014 | 2 | 2014 |
Monitoring of Bioimpedance Data during Exercise in Cyclists (P247) MV Moreno, G Moreno, F Hubert The Engineering of Sport 7, 517-524, 2008 | 2 | 2008 |
Electrical anisotropy of beef meat during ageing J Lepetit, JL Damez, MV Moreno, S Clerjon, R Favier INTERNATIONAL CONGRESS OF MEAT SCIENCE AND TECHNOLOGY 47, 308-309, 2001 | 2 | 2001 |
Optimiser sa stratégie nutritionnelle grâce à la composition corporelle MN Coux, E Ribbe, V Moreno Nutr Clin and Met 28, S90-S91, 2014 | 1 | 2014 |
La bioimpédancemétrie corporelle totale comme outil de monitoring des performances en natation Y Martinelli Université de Lausanne, Faculté des sciences sociales et politiques, 2012 | 1 | 2012 |