Følg
John M Heasman
John M Heasman
Cochlear, Sydney University
Verifisert e-postadresse på cochlear.com
Tittel
Sitert av
Sitert av
År
Effect of interphase gap and pulse duration on electrically evoked potentials is correlated with auditory nerve survival
P Prado-Guitierrez, LM Fewster, JM Heasman, CM McKay, RK Shepherd
Hearing research 215 (1-2), 47-55, 2006
1822006
A new era in electroencephalographic monitoring? Subscalp devices for ultra–long‐term recordings
J Duun‐Henriksen, M Baud, MP Richardson, M Cook, G Kouvas, ...
Epilepsia 61 (9), 1805-1817, 2020
1452020
Seizure forecasting using a novel sub-scalp ultra-long term EEG monitoring system
RE Stirling, MI Maturana, PJ Karoly, ES Nurse, K McCutcheon, ...
Frontiers in Neurology 12, 713794, 2021
722021
Clinical evaluation of expanded input dynamic range in Nucleus cochlear implants
PW Dawson, AE Vandali, MR Knight, JM Heasman
Ear and hearing 28 (2), 163-176, 2007
472007
Control of a hand grasp neuroprosthesis using an electroencephalogram-triggered switch: demonstration of improvements in performance using wavepacket analysis
JM Heasman, TRD Scott, L Kirkup, RY Flynn, VA Vare, CR Gschwind
Medical and Biological Engineering and Computing 40, 588-593, 2002
432002
Detection of fatigue in the isometric electrical activation of paralyzed hand muscles of persons with tetraplegia
JM Heasman, TRD Scott, VA Vare, RY Flynn, CR Gschwind, ...
IEEE transactions on rehabilitation engineering 8 (3), 286-296, 2000
302000
Cochlea health monitoring
JM Heasman, L Campbell, S O'leary, K Plant, KJM Verhoeven
US Patent App. 15/187,893, 2017
282017
A wavelet-based noise reduction algorithm and its clinical evaluation in cochlear implants
H Ye, G Deng, SJ Mauger, AA Hersbach, PW Dawson, JM Heasman
PloS one 8 (9), e75662, 2013
182013
Sound processing based on a confidence measure
AA Hersbach, SJ Mauger, JM Heasman, PW Dawson
US Patent 9,589,580, 2017
172017
Seizure forecasting using a novel sub-scalp ultra-long term EEG monitoring system. Front Neurol 2021; 12: 713794
RE Stirling, MI Maturana, PJ Karoly, ES Nurse, K McCutcheon, ...
82021
Magnetic stimulation in tissue-stimulating prostheses
S Mauger, B Metzenthen, J Heasman
US Patent 9,731,142, 2017
82017
Quantitative evaluation of two methods of control bilateral stimulated hand grasps in persons with tetraplegia
TRD Scott, JM Heasman, VA Vare, RY Flynn, CR Gschwind, ...
IEEE Transactions on Rehabilitation Engineering 8 (2), 259-267, 2000
82000
Monitoring stimulating assembly insertion
JM Heasman, P Gibson, S O'leary, L Campbell
US Patent 10,500,392, 2019
72019
Advanced electrode array insertion and position management
PM Carter, NC Pawsey, RO Melman, ÁR DE MIGUEL, ÁMR MACÍAS, ...
US Patent App. 15/936,282, 2018
72018
Downshifting of output in a sense prosthesis
S Lineaweaver, JM Heasman
US Patent 9,937,346, 2018
72018
Synergistic control of stimulated pronosupination with the stimulated grasp of persons with tetraplegia
TRD Scott, L Atmore, JM Heasman, RY Flynn, VA Vare, C Gschwind
IEEE Transactions on neural systems and rehabilitation engineering 9 (3 …, 2001
72001
Mechanical prosthesis with recipient physiological and prosthesis status acquisition capabilities
JM Heasman, J Walraevens
US Patent App. 15/164,494, 2017
62017
Electrode insertion tool with additional functionality
RB Murphy, PM Carter, NC Pawsey, JM Heasman, RO Melman
US Patent 10,842,531, 2020
52020
Hearing prosthesis programming
JM Heasman
US Patent 10,357,656, 2019
52019
The use of bilateral stimulated hand grasp in the bimanual activities of persons with tetraplegia
TRD Scott, VA Vare, RY Flynn, RE Quirk, JM Heasman, CR Gschwind, ...
IEEE Transactions on Rehabilitation Engineering 8 (3), 425-429, 2000
42000
Systemet kan ikke utføre handlingen. Prøv på nytt senere.
Artikler 1–20