Følg
Dr. K. V. Gobi
Tittel
Sitert av
Sitert av
År
Recent advancements in surface plasmon resonance immunosensors for detection of small molecules of biomedical, food and environmental interest
DR Shankaran, KV Gobi, N Miura
Sensors and Actuators B: Chemical 121 (1), 158-177, 2007
7952007
An electrochemical aptasensor based on functionalized graphene oxide assisted electrocatalytic signal amplification of methylene blue for aflatoxin B1 detection
KY Goud, A Hayat, G Catanante, M Satyanarayana, KV Gobi, JL Marty
Electrochimica Acta 244, 96-103, 2017
213*2017
Progress on nanostructured electrochemical sensors and their recognition elements for detection of mycotoxins: A review
KY Goud, SK Kailasa, V Kumar, YF Tsang, KV Gobi, KH Kim
Biosensors and Bioelectronics 121, 205-222, 2018
2002018
Self-assembled PEG monolayer based SPR immunosensor for label-free detection of insulin
KV Gobi, H Iwasaka, N Miura
Biosensors and Bioelectronics 22 (7), 1382-1389, 2007
1692007
Disposable and portable electrochemical aptasensor for label free detection of aflatoxin B1 in alcoholic beverages
KY Goud, G Catanante, A Hayat, M Satyanarayana, KV Gobi, JL Marty
Sensors and Actuators B: Chemical 235, 466-473, 2016
1342016
Surface plasmon resonance immunosensor for highly sensitive detection of 2, 4, 6-trinitrotoluene
DR Shankaran, KV Gobi, T Sakai, K Matsumoto, K Toko, N Miura
Biosensors and Bioelectronics 20 (9), 1750-1756, 2005
1342005
A review on recent developments in optical and electrochemical aptamer-based assays for mycotoxins using advanced nanomaterials
KY Goud, KK Reddy, M Satyanarayana, S Kummari, KV Gobi
Microchimica Acta 187 (1), 1-32, 2020
1332020
Efficient mediatorless superoxide sensors using cytochrome c-modified electrodes: surface nano-organization for selectivity and controlled peroxidase activity
KV Gobi, F Mizutani
Journal of Electroanalytical Chemistry 484 (2), 172-181, 2000
1212000
Highly sensitive and selective surface plasmon resonance sensor for detection of sub-ppb levels of benzo [a] pyrene by indirect competitive immunoreaction method
N Miura, M Sasaki, KV Gobi, C Kataoka, Y Shoyama
Biosensors and Bioelectronics 18 (7), 953-959, 2003
1192003
Disposable and portable electrochemical aptasensor for label free detection of aflatoxin B1 in alcoholic beverages
KY Goud, G Catanante, A Hayat, M Satyanarayana, KV Gobi, JL Marty
Sensors and Actuators B: Chemical 235, 466-473, 2016
1162016
Novel miniature SPR immunosensor equipped with all-in-one multi-microchannel sensor chip for detecting low-molecular-weight analytes
SJ Kim, KV Gobi, H Iwasaka, H Tanaka, N Miura
Biosensors and Bioelectronics 23 (5), 701-707, 2007
1162007
Layer-by-layer construction of an active multilayer enzyme electrode applicable for direct amperometric determination of cholesterol
K Vengatajalabathy Gobi, F Mizutani
Sensors and Actuators B: Chemical 80 (3), 272-277, 2001
932001
Electrochemical diagnostics of infectious viral diseases: Trends and challenges
KY Goud, KK Reddy, A Khorshed, VS Kumar, RK Mishra, M Oraby, ...
Biosensors and Bioelectronics 180, 113112, 2021
902021
Highly sensitive regenerable immunosensor for label-free detection of 2, 4-dichlorophenoxyacetic acid at ppb levels by using surface plasmon resonance imaging
KV Gobi, H Tanaka, Y Shoyama, N Miura
Sensors and Actuators B: Chemical 111, 562-571, 2005
882005
Surface plasmon resonance biosensor for dopamine using D3 dopamine receptor as a biorecognition molecule
S Kumbhat, DR Shankaran, SJ Kim, KV Gobi, V Joshi, N Miura
Biosensors and Bioelectronics 23 (3), 421-427, 2007
862007
Fabrication of a novel immunosensor using functionalized self-assembled monolayer for trace level detection of TNT by surface plasmon resonance
T Kawaguchi, DR Shankaran, SJ Kim, KV Gobi, K Matsumoto, K Toko, ...
Talanta 72 (2), 554-560, 2007
852007
Highly sensitive surface plasmon resonance immunosensor for parts-per-trillion level detection of 2, 4, 6-trinitrophenol
DR Shankaran, KV Gobi, K Matsumoto, T Imato, K Toko, N Miura
Sensors and Actuators B: Chemical 100 (3), 450-454, 2004
822004
Compact surface plasmon resonance (SPR) immunosensor using multichannel for simultaneous detection of small molecule compounds
H Kawazumi, KV Gobi, K Ogino, H Maeda, N Miura
Sensors and Actuators B: Chemical 108 (1-2), 791-796, 2005
802005
Recent trends in electrochemical sensors for vital biomedical markers using hybrid nanostructured materials
KK Reddy, H Bandal, M Satyanarayana, KY Goud, KV Gobi, ...
Advanced Science 7 (13), 1902980, 2020
772020
Continuous flow immunosensor for highly selective and real-time detection of sub-ppb levels of 2-hydroxybiphenyl by using surface plasmon resonance imaging
KV Gobi, H Tanaka, Y Shoyama, N Miura
Biosensors and Bioelectronics 20 (2), 350-357, 2004
742004
Systemet kan ikke utføre handlingen. Prøv på nytt senere.
Artikler 1–20