Precise and real-time measurement of 3D tumor motion in lung due to breathing and heartbeat, measured during radiotherapy Y Seppenwoolde, H Shirato, K Kitamura, S Shimizu, M Van Herk, ... International Journal of Radiation Oncology* Biology* Physics 53 (4), 822-834, 2002 | 1789 | 2002 |
Physical aspects of a real-time tumor-tracking system for gated radiotherapy H Shirato, S Shimizu, T Kunieda, K Kitamura, M Van Herk, K Kagei, ... International Journal of Radiation Oncology* Biology* Physics 48 (4), 1187-1195, 2000 | 797 | 2000 |
Four-dimensional treatment planning and fluoroscopic real-time tumor tracking radiotherapy for moving tumor H Shirato, S Shimizu, K Kitamura, T Nishioka, K Kagei, S Hashimoto, ... International Journal of Radiation Oncology* Biology* Physics 48 (2), 435-442, 2000 | 631 | 2000 |
Prediction of respiratory tumour motion for real-time image-guided radiotherapy GC Sharp, SB Jiang, S Shimizu, H Shirato Physics in Medicine & Biology 49 (3), 425, 2004 | 509 | 2004 |
Intrafractional tumor motion: lung and liver H Shirato, Y Seppenwoolde, K Kitamura, R Onimura, S Shimizu Seminars in radiation oncology 14 (1), 10-18, 2004 | 491 | 2004 |
Detection of lung tumor movement in real-time tumor-tracking radiotherapy S Shimizu, H Shirato, S Ogura, H Akita-Dosaka, K Kitamura, T Nishioka, ... International Journal of Radiation Oncology* Biology* Physics 51 (2), 304-310, 2001 | 392 | 2001 |
Impact of respiratory movement on the computed tomographic images of small lung tumors in three-dimensional (3D) radiotherapy S Shimizu, H Shirato, K Kagei, T Nishioka, X Bo, H Dosaka-Akita, ... International Journal of Radiation Oncology* Biology* Physics 46 (5), 1127-1133, 2000 | 350 | 2000 |
Real-time tumour-tracking radiotherapy. H Shirato, S Shimizu The Lancet 353 (9161), 1331-1332, 1999 | 327 | 1999 |
Tolerance of organs at risk in small-volume, hypofractionated, image-guided radiotherapy for primary and metastatic lung cancers R Onimaru, H Shirato, S Shimizu, K Kitamura, B Xu, S Fukumoto, ... International Journal of Radiation Oncology* Biology* Physics 56 (1), 126-135, 2003 | 320 | 2003 |
Three-dimensional intrafractional movement of prostate measured during real-time tumor-tracking radiotherapy in supine and prone treatment positions K Kitamura, H Shirato, Y Seppenwoolde, R Onimaru, M Oda, K Fujita, ... International Journal of Radiation Oncology* Biology* Physics 53 (5), 1117-1123, 2002 | 249 | 2002 |
Use of an implanted marker and real-time tracking of the marker for the positioning of prostate and bladder cancers S Shimizu, H Shirato, K Kitamura, N Shinohara, T Harabayashi, ... International Journal of Radiation Oncology* Biology* Physics 48 (5), 1591-1597, 2000 | 248 | 2000 |
Registration accuracy and possible migration of internal fiducial gold marker implanted in prostate and liver treated with real-time tumor-tracking radiation therapy (RTRT) K Kitamura, H Shirato, S Shimizu, N Shinohara, T Harabayashi, T Shimizu, ... Radiotherapy and oncology 62 (3), 275-281, 2002 | 236 | 2002 |
Real‐time tumor‐tracking radiation therapy for lung carcinoma by the aid of insertion of a gold marker using bronchofiberscopy T Harada, H Shirato, S Ogura, S Oizumi, K Yamazaki, S Shimizu, ... Cancer 95 (8), 1720-1727, 2002 | 216 | 2002 |
Tumor location, cirrhosis, and surgical history contribute to tumor movement in the liver, as measured during stereotactic irradiation using a real-time tumor-tracking … K Kitamura, H Shirato, Y Seppenwoolde, T Shimizu, Y Kodama, H Endo, ... International Journal of Radiation Oncology* Biology* Physics 56 (1), 221-228, 2003 | 175 | 2003 |
Three-dimensional movement of a liver tumor detected by high-speed magnetic resonance imaging S Shimizu, H Shirato, B Xo, K Kagei, T Nishioka, S Hashimoto, K Tsuchiya, ... Radiotherapy and oncology 50 (3), 367-370, 1999 | 157 | 1999 |
Development of novel tertiary amine absorbents for CO2 capture FA Chowdhury, H Okabe, S Shimizu, M Onoda, Y Fujioka Energy Procedia 1 (1), 1241-1248, 2009 | 136 | 2009 |
A proton beam therapy system dedicated to spot-scanning increases accuracy with moving tumors by real-time imaging and gating and reduces equipment size S Shimizu, N Miyamoto, T Matsuura, Y Fujii, M Umezawa, K Umegaki, ... PloS one 9 (4), e94971, 2014 | 122 | 2014 |
High-speed magnetic resonance imaging for four-dimensional treatment planning of conformal radiotherapy of moving body tumors S Shimizu, H Shirato, H Aoyama, S Hashimoto, T Nishioka, A Yamazaki, ... International Journal of Radiation Oncology* Biology* Physics 48 (2), 471-474, 2000 | 117 | 2000 |
Intrafractional baseline shift or drift of lung tumor motion during gated radiation therapy with a real-time tumor-tracking system S Takao, N Miyamoto, T Matsuura, R Onimaru, N Katoh, T Inoue, ... International Journal of Radiation Oncology* Biology* Physics 94 (1), 172-180, 2016 | 105 | 2016 |
Organ motion in image-guided radiotherapy: lessons from real-time tumor-tracking radiotherapy H Shirato, S Shimizu, K Kitamura, R Onimaru International Journal of Clinical Oncology 12, 8-16, 2007 | 99 | 2007 |