팔로우
Yoon-Bo Shim, 심윤보
제목
인용
인용
연도
Electrochemical sensors based on organic conjugated polymers
MA Rahman, P Kumar, DS Park, YB Shim
Sensors 8 (1), 118-141, 2008
5922008
Applications of conducting polymer composites to electrochemical sensors: A review
MH Naveen, NG Gurudatt, YB Shim
Applied materials today 9, 419-433, 2017
4452017
Conducting polymer-based electrochemical biosensors for neurotransmitters: A review
JM Moon, N Thapliyal, KK Hussain, RN Goyal, YB Shim
Biosensors and Bioelectronics 102, 540-552, 2018
3692018
Ultrasensitive and selective electrochemical diagnosis of breast cancer based on a hydrazine–Au nanoparticle–aptamer bioconjugate
Y Zhu, P Chandra, YB Shim
Analytical chemistry 85 (2), 1058-1064, 2013
3172013
Electrochemistry of conductive polymers VIII: In situ spectroelectrochemical studies of polyaniline growth mechanisms
YB Shim, MS Won, SM Park
Journal of the Electrochemical Society 137 (2), 538, 1990
2981990
Direct DNA hybridization detection based on the oligonucleotide-functionalized conductive polymer
TY Lee, YB Shim
Analytical chemistry 73 (22), 5629-5632, 2001
2812001
Disposable amperometric immunosensor system for rabbit IgG using a conducting polymer modified screen-printed electrode
F Darain, SU Park, YB Shim
Biosensors and Bioelectronics 18 (5-6), 773-780, 2003
2502003
Label-free detection of kanamycin based on the aptamer-functionalized conducting polymer/gold nanocomposite
Y Zhu, P Chandra, KM Song, C Ban, YB Shim
Biosensors and Bioelectronics 36 (1), 29-34, 2012
2462012
Characterization of an EDTA bonded conducting polymer modified electrode: its application for the simultaneous determination of heavy metal ions
MA Rahman, MS Won, YB Shim
Analytical chemistry 75 (5), 1123-1129, 2003
2322003
Comparison of enzymatic and non-enzymatic glucose sensors based on hierarchical Au-Ni alloy with conductive polymer
WC Lee, KB Kim, NG Gurudatt, KK Hussain, CS Choi, DS Park, YB Shim
Biosensors and Bioelectronics 130, 48-54, 2019
2222019
Functionalized conducting polymer as an enzyme-immobilizing substrate: an amperometric glutamate microbiosensor for in vivo measurements
MA Rahman, NH Kwon, MS Won, ES Choe, YB Shim
Analytical Chemistry 77 (15), 4854-4860, 2005
2012005
Direct electrochemistry of horseradish peroxidase bonded on a conducting polymer modified glassy carbon electrode
YT Kong, M Boopathi, YB Shim
Biosensors and Bioelectronics 19 (3), 227-232, 2003
1982003
A sensor for acetaminophen in a blood medium using a Cu (II)-conducting polymer complex modified electrode
M Boopathi, MS Won, YB Shim
Analytica Chimica Acta 512 (2), 191-197, 2004
1782004
Simultaneous determination of ascorbic acid, dopamine, uric acid and folic acid based on activated graphene/MWCNT nanocomposite loaded Au nanoclusters
AA Abdelwahab, YB Shim
Sensors and Actuators B: Chemical 221, 659-665, 2015
1762015
Direct electrochemistry of laccase immobilized on Au nanoparticles encapsulated-dendrimer bonded conducting polymer: application for a catechin sensor
MA Rahman, HB Noh
Analytical chemistry 80 (21), 8020-8027, 2008
1752008
Application of a Cu–Co alloy dendrite on glucose and hydrogen peroxide sensors
HB Noh, KS Lee, P Chandra, MS Won, YB Shim
Electrochimica Acta 61, 36-43, 2012
1742012
Template Free Preparation of Heteroatoms Doped Carbon Spheres with Trace Fe for Efficient Oxygen Reduction Reaction and Supercapacitor.
MH Naveen, K Shim, MSA Hossain, JH Kim, YB Shim
Advanced Energy Materials 7 (5), 2017
1722017
A lactate biosensor based on lactate dehydrogenase/nictotinamide adenine dinucleotide (oxidized form) immobilized on a conducting polymer/multiwall carbon nanotube composite film
MM Rahman, MJA Shiddiky, MA Rahman, YB Shim
Analytical biochemistry 384 (1), 159-165, 2009
1702009
Detection of daunomycin using phosphatidylserine and aptamer co-immobilized on Au nanoparticles deposited conducting polymer
P Chandra, HB Noh, MS Won, YB Shim
Biosensors and Bioelectronics 26 (11), 4442-4449, 2011
1662011
Gold nanoparticles doped conducting polymer nanorod electrodes: ferrocene catalyzed aptamer-based thrombin immunosensor
MA Rahman, JI Son, MS Won, YB Shim
Analytical chemistry 81 (16), 6604-6611, 2009
1652009
현재 시스템이 작동되지 않습니다. 나중에 다시 시도해 주세요.
학술자료 1–20