Segui
Evan Hirst
Evan Hirst
Email verificata su callaghaninnovation.govt.nz
Titolo
Citata da
Citata da
Anno
Laser speckle contrast imaging: theoretical and practical limitations
D Briers, DD Duncan, E Hirst, SJ Kirkpatrick, M Larsson, W Steenbergen, ...
Journal of biomedical optics 18 (6), 066018-066018, 2013
5722013
Non-invasive detection of anaemia using digital photographs of the conjunctiva
S Collings, O Thompson, E Hirst, L Goossens, A George, R Weinkove
PloS one 11 (4), e0153286, 2016
1192016
Correction for spatial averaging in laser speckle contrast analysis
O Thompson, M Andrews, E Hirst
Biomedical optics express 2 (4), 1021-1029, 2011
952011
Bond-rupture immunosensors—A review
ER Hirst, YJ Yuan, WL Xu, JE Bronlund
Biosensors and Bioelectronics 23 (12), 1759-1768, 2008
832008
Bond rupture of biomolecular interactions by resonant quartz crystal
YJ Yuan, MJ van der Werff, H Chen, ER Hirst, WL Xu, JE Bronlund
Analytical chemistry 79 (23), 9039-9044, 2007
342007
Quartz crystal microbalance induced bond rupture sensing for medical diagnostics
MJ Van Der Werff, YJ Yuan, ER Hirst, WL Xu, H Chen, JE Bronlund
IEEE Sensors Journal 7 (5), 762-769, 2007
272007
Surface acoustic wave delay line for biosensor application
ER Hirst, WL Xu, JE Bronlund, YJ Yuan
2008 15th International Conference on Mechatronics and Machine Vision in …, 2008
112008
Object measurement system
GP McIver, AB Reid, ER Hirst
US Patent App. 15/733,100, 2020
82020
Sparse reproducible machine learning for near infrared hyperspectral imaging: Estimating the tetrahydrocannabinolic acid concentration in Cannabis sativa L.
SK Abeysekera, A Robinson, MPL Ooi, YC Kuang, M Manley-Harris, ...
Industrial Crops and Products 192, 116137, 2023
72023
Surface acoustic wave delay line for bond rupture biosensors
ER Hirst, WL Xu, JE Bronlund, YJ Yuan
IEEE Sensors Journal 11 (11), 2952-2956, 2011
62011
WiendeltSteenbergen, Tomas Stromberg, and Oliver B. Thompson, Laser speckle contrast imaging: theoretical and practical limitations
D Briers, DD Duncan, E Hirst, SJ Kirkpatrick, M Larsson
Journal of Biomedical Optics 18 (6), 066018, 0
4
Is there a difference between laser speckle and laser Doppler in depth sensitivity?
OB Thompson, ER Hirst, MK Andrews
Dynamics and Fluctuations in Biomedical Photonics VIII 7898, 64-69, 2011
32011
Measurement of dynamic scattering beneath stationary layers using multiple-exposure laser speckle contrast analysis
E Hirst, O Thompson, M Andrews
Dynamics and Fluctuations in Biomedical Photonics X 8580, 18-24, 2013
12013
Measurement of directed blood flow by laser speckle
ER Hirst, OB Thompson, MK Andrews
Dynamics and Fluctuations in Biomedical Photonics VIII 7898, 55-63, 2011
12011
Conduit identifying method and apparatus
PD Harris, ER Hirst, RJ Petherick, S Rainthorpe, OB Thompson
US Patent App. 16/968,481, 2020
2020
Effective frequency sensitivity of laser speckle contrast measurements
OB Thompson, ER Hirst, MK Andrews
Dynamics and Fluctuations in Biomedical Photonics X 8580, 25-30, 2013
2013
Multi-exposure laser speckle perfusion imaging for retinal blood flow
E Hirst, M Andrews, O Thompson
Dynamics and Fluctuations in Biomedical Photonics IX 8222, 21-27, 2012
2012
Surface acoustic wave delay for bond rupture biosensors
ER Hirst, W Xu, JE Bronlund, YJ Yuan
IEEE, 2011
2011
Acoustic wave and bond rupture based biosensor--principle and development: a thesis presented in partial fulfilment of the requirements for the degree of Doctor of Philosophy …
E Hirst
Massey University, 2009
2009
Il sistema al momento non può eseguire l'operazione. Riprova più tardi.
Articoli 1–19