Segui
Agustin Palacios-Laloy
Agustin Palacios-Laloy
Mag4Health
Email verificata su mag4health.com - Home page
Titolo
Citata da
Citata da
Anno
Experimental violation of a Bell’s inequality in time with weak measurement
A Palacios-Laloy, F Mallet, F Nguyen, P Bertet, D Vion, D Esteve, ...
Nature Physics 6 (6), 442-447, 2010
4582010
Single-shot qubit readout in circuit quantum electrodynamics
F Mallet, FR Ong, A Palacios-Laloy, F Nguyen, P Bertet, D Vion, D Esteve
Nature Physics 5 (11), 791-795, 2009
3772009
Tunable resonators for quantum circuits
A Palacios-Laloy, F Nguyen, F Mallet, P Bertet, D Vion, D Esteve
Journal of Low Temperature Physics 151, 1034-1042, 2008
2222008
Circuit QED with a nonlinear resonator: ac-Stark shift and dephasing
FR Ong, M Boissonneault, F Mallet, A Palacios-Laloy, A Dewes, ...
Physical review letters 106 (16), 167002, 2011
1202011
Magnetoencephalography With Optically Pumped 4He Magnetometers at Ambient Temperature
E Labyt, MC Corsi, W Fourcault, AP Laloy, F Bertrand, F Lenouvel, ...
IEEE transactions on medical imaging 38 (1), 90-98, 2018
642018
Helium-4 magnetometers for room-temperature biomedical imaging: toward collective operation and photon-noise limited sensitivity
W Fourcault, R Romain, G Le Gal, F Bertrand, V Josselin, M Le Prado, ...
Optics Express 29 (10), 14467-14475, 2021
502021
Theory of a parametric-resonance magnetometer based on atomic alignment
F Beato, E Belorizky, E Labyt, M Le Prado, A Palacios-Laloy
Physical Review A 98 (5), 053431, 2018
372018
Dual-axis Hanle magnetometer based on atomic alignment with a single optical access
G Le Gal, G Lieb, F Beato, T Jager, H Gilles, A Palacios-Laloy
Physical Review Applied 12 (6), 064010, 2019
302019
A New Generation of OPM for High Dynamic and Large Bandwidth MEG: The 4He OPMs—First Applications in Healthy Volunteers
TP Gutteling, M Bonnefond, T Clausner, S Daligault, R Romain, ...
Sensors 23 (5), 2801, 2023
252023
Superconducting qubit in a resonator: test of the Legget-Garg inequality and single-shot readout
A Palacios-Laloy
Université Pierre et Marie Curie-Paris VI, 2010
252010
A 4He vector zero-field optically pumped magnetometer operated in the Earth-field
F Bertrand, T Jager, A Boness, W Fourcault, G Le Gal, A Palacios-Laloy, ...
Review of Scientific Instruments 92 (10), 2021
212021
Performance Analysis of Optically Pumped 4He Magnetometers vs. Conventional SQUIDs: From Adult to Infant Head Models
S Zahran, M Mahmoudzadeh, F Wallois, N Betrouni, P Derambure, ...
Sensors 22 (8), 3093, 2022
182022
Parametric resonance magnetometer based on elliptically polarized light yielding three-axis measurement with isotropic sensitivity
G Le Gal, LL Rouve, A Palacios-Laloy
Applied Physics Letters 118 (25), 2021
182021
Spectral measurement of the thermal excitation of a superconducting qubit
A Palacios-Laloy, F Mallet, F Nguyen, F Ong, P Bertet, D Vion, D Esteve
Physica Scripta 2009 (T137), 014015, 2009
182009
All-optical isotropic scalar 4He magnetometer based on atomic alignment
G Lieb, T Jager, A Palacios-Laloy, H Gilles
Review of Scientific Instruments 90 (7), 2019
132019
Second-order effects in parametric-resonance magnetometers based on atomic alignment
F Beato, A Palacios-Laloy
EPJ Quantum Technology 7 (1), 1-14, 2020
112020
Vector magnetometer with elliptical polarisation
AP LALOY
US Patent 10,845,438, 2020
112020
Navigational aid method, computer program product and inertial navigation system therefor
S Morales, AP Laloy, JM Leger, G Remillieux, M Gramlich, E Brunstein
US Patent 10,401,177, 2019
82019
Method for obtaining a substrate provided with a coating comprising a discontinuous thin metal layer
A Palacios-Laloy
US Patent 9,587,303, 2017
72017
Solar control glazing
LJ Singh, A Palacios-Laloy, E Sandre-Chardonnal
US Patent App. 14/386,451, 2015
72015
Il sistema al momento non può eseguire l'operazione. Riprova più tardi.
Articoli 1–20