Segui
Marek Maryanski
Marek Maryanski
President and Director of R&D at MGS Research Inc
Email verificata su mgsresearch.com
Titolo
Citata da
Citata da
Anno
NMR relaxation enhancement in gels polymerized and cross-linked by ionizing radiation: a new approach to 3D dosimetry by MRI
MJ Maryanski, JC Gore, RP Kennan, RJ Schulz
Magnetic resonance imaging 11 (2), 253-258, 1993
6651993
Magnetic resonance imaging of radiation dose distributions using a polymer-gel dosimeter
MJ Maryanski, RJ Schulz, GS Ibbott, JC Gatenby, J Xie, D Horton, ...
Physics in Medicine & Biology 39 (9), 1437, 1994
5691994
Radiation dose distributions in three dimensions from tomographic optical density scanning of polymer gels: I. Development of an optical scanner
JC Gore, M Ranade, MJ Maryanski, RJ Schulz
Physics in Medicine & Biology 41 (12), 2695, 1996
4191996
Radiation therapy dosimetry using magnetic resonance imaging of polymer gels
MJ Maryanski, GS Ibbott, P Eastman, RJ Schulz, JC Gore
Medical physics 23 (5), 699-705, 1996
3701996
Radiation dose distributions in three dimensions from tomographic optical density scanning of polymer gels: II. Optical properties of the BANG polymer gel
MJ Maryanski, YZ Zastavker, JC Gore
Physics in Medicine & Biology 41 (12), 2705, 1996
2951996
Characterisation of PRESAGE™: A new 3-D radiochromic solid polymer dosemeter for ionising radiation
J Adamovics, MJ Maryanski
Radiation protection dosimetry 120 (1-4), 107-112, 2006
2462006
Three-dimensional visualization and measurement of conformal dose distributions using magnetic resonance imaging of BANG polymer gel dosimeters
GS Ibbott, MJ Maryanski, P Eastman, SD Holcomb, Y Zhang, RG Avison, ...
International Journal of Radiation Oncology* Biology* Physics 38 (5), 1097-1103, 1997
2121997
Effects of crosslinking and temperature on the dose response of a BANG polymer gel dosimeter
MJ Maryanski, C Audet, JC Gore
Physics in Medicine & Biology 42 (2), 303, 1997
1871997
Performance of a commercial optical CT scanner and polymer gel dosimeters for 3‐D dose verification: optical CT scanning of polymer gel
Y Xu, CS Wuu, MJ Maryanski
Medical physics 31 (11), 3024-3033, 2004
1172004
The effects of cross-link density and chemical exchange on magnetization transfer in polyacrylamide gels
RP Kennan, KA Richardson, J Zhong, MJ Maryanski, JC Gore
Journal of Magnetic Resonance, Series B 110 (3), 267-277, 1996
1021996
Initial evaluation of commercial optical CT‐based 3D gel dosimeter
KTS Islam, JF Dempsey, MK Ranade, MJ Maryanski, DA Low
Medical Physics 30 (8), 2159-2168, 2003
902003
Dosimetric evaluation of a novel polymer gel dosimeter for proton therapy
OA Zeidan, SI Sriprisan, O Lopatiuk‐Tirpak, PA Kupelian, SL Meeks, ...
Medical Physics 37 (5), 2145-2152, 2010
772010
A new approach to radiochromic three-dimensional dosimetry-polyurethane
J Adamovics, MJ Maryanski
Journal of Physics: Conference Series 3 (1), 172, 2004
752004
Image registration of BANG® gel dose maps for quantitative dosimetry verification
SL Meeks, FJ Bova, MJ Maryanski, LA Kendrick, MK Ranade, JM Buatti, ...
International Journal of Radiation Oncology* Biology* Physics 43 (5), 1135-1141, 1999
721999
In vivo measurement of cortical bone lead using polarized x rays
L Wielopolski, JF Rosen, DN Slatkin, R Zhang, JA Kalef‐Ezra, ...
Medical physics 16 (4), 521-528, 1989
711989
The role of specific side groups and pH in magnetization transfer in polymers
DF Gochberg, RP Kennan, MJ Maryanski, JC Gore
Journal of magnetic resonance 131 (2), 191-198, 1998
651998
Dosimetry study of Re‐188 liquid balloon for intravascular brachytherapy using polymer gel dosimeters and laser‐beam optical CT scanner
CS Wuu, P Schiff, MJ Maryanski, T Liu, S Borzillary, J Weinberger
Medical Physics 30 (2), 132-137, 2003
622003
New 3D radiochromic solid polymer dosimeter from leuco dyes and a transparent polymeric matrix
J Adamovics, MJ Maryanski
Medical Physics 30 (6), 1349-1349, 2003
612003
Assessment of the accuracy of stereotactic radiosurgery using Fricke‐infused gels and MRI
RJ Schulz, MJ Maryanski, GS Ibbott, JE Bond
Medical physics 20 (6), 1731-1734, 1993
541993
Three-dimensional detection, dosimetry and imaging of an energy field by formation of a polymer in a gel
M Maryanski, J Gore, R Schulz
US Patent 5,321,357, 1994
531994
Il sistema al momento non può eseguire l'operazione. Riprova più tardi.