Pros and cons of ultra-high-field MRI/MRS for human application ME Ladd, P Bachert, M Meyerspeer, E Moser, AM Nagel, DG Norris, ... Progress in nuclear magnetic resonance spectroscopy 109, 1-50, 2018 | 539 | 2018 |
Inverse Z‐spectrum analysis for spillover‐, MT‐, and T1‐corrected steady‐state pulsed CEST‐MRI – application to pH‐weighted MRI of acute stroke M Zaiss, J Xu, S Goerke, IS Khan, RJ Singer, JC Gore, DF Gochberg, ... NMR in biomedicine 27 (3), 240-252, 2014 | 359 | 2014 |
Chemical exchange saturation transfer (CEST) and MR Z-spectroscopy in vivo: a review of theoretical approaches and methods M Zaiss, P Bachert Physics in Medicine & Biology 58 (22), R221, 2013 | 358 | 2013 |
Quantitative separation of CEST effect from magnetization transfer and spillover effects by Lorentzian-line-fit analysis of z-spectra M Zaiß, B Schmitt, P Bachert Journal of magnetic resonance 211 (2), 149-155, 2011 | 352 | 2011 |
Correction of B1‐inhomogeneities for relaxation‐compensated CEST imaging at 7 T J Windschuh, M Zaiss, JE Meissner, D Paech, A Radbruch, ME Ladd, ... NMR in biomedicine 28 (5), 529-537, 2015 | 267 | 2015 |
An overview of CEST MRI for non-MR physicists B Wu, G Warnock, M Zaiss, C Lin, M Chen, Z Zhou, L Mu, D Nanz, ... EJNMMI physics 3, 1-21, 2016 | 261 | 2016 |
Relaxation-compensated CEST-MRI of the human brain at 7 T: unbiased insight into NOE and amide signal changes in human glioblastoma M Zaiss, J Windschuh, D Paech, JE Meissner, S Burth, B Schmitt, ... Neuroimage 112, 180-188, 2015 | 248 | 2015 |
Exchange‐dependent relaxation in the rotating frame for slow and intermediate exchange–modeling off‐resonant spin‐lock and chemical exchange saturation transfer M Zaiss, P Bachert NMR in Biomedicine 26 (5), 507-518, 2013 | 244 | 2013 |
Simultaneous mapping of water shift and B1(WASABI)—Application to field‐Inhomogeneity correction of CEST MRI data P Schuenke, J Windschuh, V Roeloffs, ME Ladd, P Bachert, M Zaiss Magnetic resonance in medicine 77 (2), 571-580, 2017 | 193 | 2017 |
On the origins of chemical exchange saturation transfer (CEST) contrast in tumors at 9.4 T J Xu, M Zaiss, Z Zu, H Li, J Xie, DF Gochberg, P Bachert, JC Gore NMR in biomedicine 27 (4), 406-416, 2014 | 174 | 2014 |
A combined analytical solution for chemical exchange saturation transfer and semi‐solid magnetization transfer M Zaiss, Z Zu, J Xu, P Schuenke, DF Gochberg, JC Gore, ME Ladd, ... NMR in biomedicine 28 (2), 217-230, 2015 | 160 | 2015 |
Assessing the predictability of IDH mutation and MGMT methylation status in glioma patients using relaxation-compensated multipool CEST MRI at 7.0 T D Paech, J Windschuh, J Oberhollenzer, C Dreher, F Sahm, JE Meissner, ... Neuro-oncology 20 (12), 1661-1671, 2018 | 152 | 2018 |
Downfield‐NOE‐suppressed amide‐CEST‐MRI at 7 Tesla provides a unique contrast in human glioblastoma M Zaiss, J Windschuh, S Goerke, D Paech, JE Meissner, S Burth, ... Magnetic resonance in medicine 77 (1), 196-208, 2017 | 149 | 2017 |
Snapshot‐CEST: optimizing spiral‐centric‐reordered gradient echo acquisition for fast and robust 3D CEST MRI at 9.4 T M Zaiss, P Ehses, K Scheffler NMR in Biomedicine 31 (4), e3879, 2018 | 125 | 2018 |
Review and consensus recommendations on clinical APT‐weighted imaging approaches at 3T: application to brain tumors J Zhou, M Zaiss, L Knutsson, PZ Sun, SS Ahn, S Aime, P Bachert, ... Magnetic resonance in medicine 88 (2), 546-574, 2022 | 123 | 2022 |
T1ρ-weighted dynamic glucose-enhanced MR imaging in the human brain D Paech, P Schuenke, C Koehler, J Windschuh, S Mundiyanapurath, ... Radiology 285 (3), 914-922, 2017 | 112 | 2017 |
Optimization of pulse train presaturation for CEST imaging in clinical scanners B Schmitt, M Zaiß, J Zhou, P Bachert Magnetic resonance in medicine 65 (6), 1620-1629, 2011 | 110 | 2011 |
QUESP and QUEST revisited–fast and accurate quantitative CEST experiments M Zaiss, G Angelovski, E Demetriou, MT McMahon, X Golay, K Scheffler Magnetic resonance in medicine 79 (3), 1708-1721, 2018 | 109 | 2018 |
Adiabatically prepared spin‐lock approach for T1ρ‐based dynamic glucose enhanced MRI at ultrahigh fields P Schuenke, C Koehler, A Korzowski, J Windschuh, P Bachert, ME Ladd, ... Magnetic resonance in medicine 78 (1), 215-225, 2017 | 109 | 2017 |
Characterization of creatine guanidinium proton exchange by water‐exchange (WEX) spectroscopy for absolute‐pH CEST imaging in vitro S Goerke, M Zaiss, P Bachert NMR in Biomedicine 27 (5), 507-518, 2014 | 104 | 2014 |