Early failure of metal-on-metal bearings in hip resurfacing and large-diameter total hip replacement: a consequence of excess wear DJ Langton, SS Jameson, TJ Joyce, NJ Hallab, S Natu, AVF Nargol The Journal of Bone & Joint Surgery British Volume 92 (1), 38-46, 2010 | 897 | 2010 |
Adverse reaction to metal debris following hip resurfacing: the influence of component type, orientation and volumetric wear DJ Langton, TJ Joyce, SS Jameson, J Lord, M Van Orsouw, JP Holland, ... The Journal of Bone & Joint Surgery British Volume 93 (2), 164-171, 2011 | 513 | 2011 |
Accelerating failure rate of the ASR total hip replacement DJ Langton, SS Jameson, TJ Joyce, JN Gandhi, R Sidaginamale, ... The Journal of Bone & Joint Surgery British Volume 93 (8), 1011-1016, 2011 | 457 | 2011 |
The effect of component size and orientation on the concentrations of metal ions after resurfacing arthroplasty of the hip DJ Langton, SS Jameson, TJ Joyce, J Webb, AVF Nargol The Journal of Bone & Joint Surgery British Volume 90 (9), 1143-1151, 2008 | 397 | 2008 |
Taper junction failure in large-diameter metal-on-metal bearings DJ Langton, R Sidaginamale, JK Lord, AVF Nargol, TJ Joyce Bone & joint research 1 (4), 56-63, 2012 | 314 | 2012 |
High failure rates with a large-diameter hybrid metal-on-metal total hip replacement: clinical, radiological and retrieval analysis B Bolland, DJ Culliford, DJ Langton, JPS Millington, NK Arden, ... The Journal of Bone & Joint Surgery British Volume 93 (5), 608-615, 2011 | 311 | 2011 |
Blood metal ion concentrations after hip resurfacing arthroplasty: a comparative study of articular surface replacement and Birmingham Hip Resurfacing arthroplasties DJ Langton, AP Sprowson, TJ Joyce, M Reed, I Carluke, P Partington, ... The Journal of Bone & Joint Surgery British Volume 91 (10), 1287-1295, 2009 | 283 | 2009 |
Adverse reactions to metal debris: histopathological features of periprosthetic soft tissue reactions seen in association with failed metal on metal hip arthroplasties S Natu, RP Sidaginamale, J Gandhi, DJ Langton, AVF Nargol Journal of clinical pathology 65 (5), 409-418, 2012 | 208 | 2012 |
European multidisciplinary consensus statement on the use and monitoring of metal-on-metal bearings for total hip replacement and hip resurfacing F Hannemann, A Hartmann, J Schmitt, J Lützner, A Seidler, P Campbell, ... Orthopaedics & Traumatology: Surgery & Research 99 (3), 263-271, 2013 | 165 | 2013 |
A common allele of HLA is associated with asymptomatic SARS-CoV-2 infection DG Augusto, LD Murdolo, DSM Chatzileontiadou, JJ Sabatino Jr, ... Nature 620 (7972), 128-136, 2023 | 153 | 2023 |
The influence of HLA genotype on the severity of COVID‐19 infection DJ Langton, SC Bourke, BA Lie, G Reiff, S Natu, R Darlay, J Burn, ... Hla 98 (1), 14-22, 2021 | 124 | 2021 |
The clinical implications of elevated blood metal ion concentrations in asymptomatic patients with MoM hip resurfacings: a cohort study DJ Langton, RP Sidaginamale, TJ Joyce, S Natu, P Blain, RD Jefferson, ... BMJ open 3 (3), e001541, 2013 | 120 | 2013 |
Blood metal ion testing is an effective screening tool to identify poorly performing metal-on-metal bearing surfaces RP Sidaginamale, TJ Joyce, JK Lord, R Jefferson, PG Blain, AVF Nargol, ... Bone & joint research 2 (5), 84-95, 2013 | 118 | 2013 |
Ten-year clinical, radiological and metal ion analysis of the Birmingham Hip Resurfacing: from a single, non-designer surgeon JP Holland, DJ Langton, M Hashmi The Journal of Bone & Joint Surgery British Volume 94 (4), 471-476, 2012 | 115 | 2012 |
Cup anteversion in hip resurfacing: validation of EBRA and the presentation of a simple clinical grading system DJ Langton, AP Sprowson, D Mahadeva, S Bhatnagar, JP Holland, ... The Journal of arthroplasty 25 (4), 607-613, 2010 | 105 | 2010 |
Articular surface replacement of the hip: a prospective single-surgeon series SS Jameson, DJ Langton, AVF Nargol The Journal of Bone & Joint Surgery British Volume 92 (1), 28-37, 2010 | 84 | 2010 |
Why does titanium alloy wear cobalt chrome alloy despite lower bulk hardness: A nanoindentation study? N Moharrami, DJ Langton, O Sayginer, SJ Bull Thin Solid Films 549, 79-86, 2013 | 83 | 2013 |
Volumetric wear assessment of failed metal-on-metal hip resurfacing prostheses JK Lord, DJ Langton, AVF Nargol, TJ Joyce Wear 272 (1), 79-87, 2011 | 82 | 2011 |
Ongoing problems with metal-on-metal hip implants C Heneghan, D Langton, M Thompson Bmj 344, 2012 | 80 | 2012 |
A large taper mismatch is one of the key factors behind high wear rates and failure at the taper junction of total hip replacements: A finite element wear analysis A Ashkanfar, DJ Langton, TJ Joyce Journal of the mechanical behavior of biomedical materials 69, 257-266, 2017 | 72 | 2017 |