Follow
Puers Robert
Puers Robert
Verified email at esat.kuleuven.be - Homepage
Title
Cited by
Cited by
Year
A review of focused ion beam applications in microsystem technology
S Reyntjens, R Puers
Journal of micromechanics and microengineering 11 (4), 287, 2001
10112001
A 60 W 60 nV/Hz Readout Front-End for Portable Biopotential Acquisition Systems
RF Yazicioglu, P Merken, R Puers, C Van Hoof
IEEE Journal of Solid-State Circuits 42 (5), 1100-1110, 2007
5712007
Pull-in voltage analysis of electrostatically actuated beam structures with fixed–fixed and fixed–free end conditions
S Pamidighantam, R Puers, K Baert, HAC Tilmans
Journal of Micromechanics and Microengineering 12 (4), 458, 2002
5262002
A review of MEMS oscillators for frequency reference and timing applications
JTM Van Beek, R Puers
Journal of Micromechanics and Microengineering 22 (1), 013001, 2011
5072011
Capacitive sensors: when and how to use them
R Puers
Sensors and Actuators A: Physical 37, 93-105, 1993
4611993
Towards the integration of textile sensors in a wireless monitoring suit
M Catrysse, R Puers, C Hertleer, L Van Langenhove, H Van Egmond, ...
Sensors and Actuators A: Physical 114 (2-3), 302-311, 2004
4352004
Inductive powering: basic theory and application to biomedical systems
K Van Schuylenbergh, R Puers
Springer Netherlands, 2009
4082009
A 200 W Eight-Channel EEG Acquisition ASIC for Ambulatory EEG Systems
RF Yazicioglu, P Merken, R Puers, C Van Hoof
IEEE Journal of Solid-State Circuits 43 (12), 3025-3038, 2008
3862008
Magnitude and distribution of occlusal forces on oral implants supporting fixed prostheses: an in vivo study
J Duyck, H Van Oosterwyck, J Vander Sloten, M De Cooman, R Puers, ...
Clinical oral implants research 11 (5), 465-475, 2000
3832000
The influence of bone mechanical properties and implant fixation upon bone loading around oral implants
H Van Oosterwyck, J Duyck, J Vander Sloten, G Van der Perre, ...
Clinical oral implants research 9 (6), 407-418, 1998
3601998
An implantable 455-active-electrode 52-channel CMOS neural probe
CM Lopez, A Andrei, S Mitra, M Welkenhuysen, W Eberle, C Bartic, ...
IEEE Journal of Solid-State Circuits 49 (1), 248-261, 2013
3182013
Fabrication, modelling and characterization of MEMS piezoelectric vibration harvesters
M Renaud, K Karakaya, T Sterken, P Fiorini, C Van Hoof, R Puers
Sensors and Actuators A: Physical 145, 380-386, 2008
3132008
Implant design and interface force transfer: a photoelastic and strain‐gauge analysis
M Cehreli, J Duyck, MD Cooman, R Puers, I Naert
Clinical Oral Implants Research 15 (2), 249-257, 2004
3112004
A comprehensive model to predict the charging and reliability of capacitive RF MEMS switches
WM Van Spengen, R Puers, R Mertens, I De Wolf
Journal of Micromechanics and Microengineering 14 (4), 514, 2004
3102004
A physical model to predict stiction in MEMS
WM Van Spengen, R Puers, I De Wolf
Journal of micromechanics and microengineering 12 (5), 702, 2002
2922002
Pseudo-two-dimensional model for double-gate tunnel FETs considering the junctions depletion regions
MG Bardon, HP Neves, R Puers, C Van Hoof
IEEE Transactions on Electron Devices 57 (4), 827-834, 2010
2842010
An inductive power link for a wireless endoscope
B Lenaerts, R Puers
Biosensors and Bioelectronics 22 (7), 1390-1395, 2007
2762007
An inductive power system with integrated bi-directional data-transmission
M Catrysse, B Hermans, R Puers
Sensors and Actuators A: Physical 115 (2-3), 221-229, 2004
2702004
Integrating wireless ECG monitoring in textiles
J Coosemans, B Hermans, R Puers
Sensors and Actuators A: Physical 130, 48-53, 2006
2532006
Time multiplexed active neural probe with 1356 parallel recording sites
BC Raducanu, RF Yazicioglu, CM Lopez, M Ballini, J Putzeys, S Wang, ...
Sensors 17 (10), 2388, 2017
2262017
The system can't perform the operation now. Try again later.
Articles 1–20