4D flow cardiovascular magnetic resonance consensus statement P Dyverfeldt, M Bissell, AJ Barker, AF Bolger, CJ Carlhäll, T Ebbers, ... Journal of Cardiovascular Magnetic Resonance 17 (1), 72, 2015 | 1006 | 2015 |
Medical students' attitude towards artificial intelligence: a multicentre survey D Pinto dos Santos, D Giese, S Brodehl, SH Chon, W Staab, R Kleinert, ... European radiology 29, 1640-1646, 2019 | 624 | 2019 |
A new imaging method for assessment of aortic dissection using four-dimensional phase contrast magnetic resonance imaging RE Clough, M Waltham, D Giese, PR Taylor, T Schaeffter Journal of vascular surgery 55 (4), 914-923, 2012 | 186 | 2012 |
High resolution three‐dimensional cardiac perfusion imaging using compartment‐based k‐t principal component analysis V Vitanis, R Manka, D Giese, H Pedersen, S Plein, P Boesiger, S Kozerke Magnetic resonance in medicine 65 (2), 575-587, 2011 | 104 | 2011 |
Quantitative analysis of vortical blood flow in the thoracic aorta using 4D phase contrast MRI J von Spiczak, G Crelier, D Giese, S Kozerke, D Maintz, AC Bunck PloS one 10 (9), e0139025, 2015 | 99 | 2015 |
Hybrid ultrasound MRI for improved cardiac imaging and real‐time respiration control DA Feinberg, D Giese, DA Bongers, S Ramanna, M Zaitsev, M Markl, ... Magnetic Resonance in Medicine: An Official Journal of the International …, 2010 | 98 | 2010 |
Analysis and correction of background velocity offsets in phase‐contrast flow measurements using magnetic field monitoring D Giese, M Haeberlin, C Barmet, KP Pruessmann, T Schaeffter, ... Magnetic resonance in medicine 67 (5), 1294-1302, 2012 | 83 | 2012 |
Reconstruction of divergence‐free velocity fields from cine 3D phase‐contrast flow measurements J Busch, D Giese, L Wissmann, S Kozerke Magnetic resonance in medicine 69 (1), 200-210, 2013 | 74 | 2013 |
Accelerated MRI of the lumbar spine using compressed sensing: quality and efficiency G Bratke, R Rau, K Weiss, C Kabbasch, K Sircar, JN Morelli, T Persigehl, ... Journal of Magnetic Resonance Imaging 49 (7), e164-e175, 2019 | 72 | 2019 |
Towards highly accelerated Cartesian time-resolved 3D flow cardiovascular magnetic resonance in the clinical setting D Giese, J Wong, GF Greil, M Buehrer, T Schaeffter, S Kozerke Journal of Cardiovascular Magnetic Resonance 16 (1), 42, 2014 | 67 | 2014 |
Image‐based background phase error correction in 4D flow MRI revisited J Busch, D Giese, S Kozerke Journal of Magnetic Resonance Imaging 46 (5), 1516-1525, 2017 | 61 | 2017 |
Accelerated aortic 4D flow cardiovascular magnetic resonance using compressed sensing: applicability, validation and clinical integration E Neuhaus, K Weiss, R Bastkowski, J Koopmann, D Maintz, D Giese Journal of Cardiovascular Magnetic Resonance 21 (1), 65, 2019 | 59 | 2019 |
Highly undersampled phase‐contrast flow measurements using compartment‐based k–t principal component analysis D Giese, T Schaeffter, S Kozerke Magnetic resonance in medicine 69 (2), 434-443, 2013 | 57 | 2013 |
Improved UTE‐based attenuation correction for cranial PET‐MR using dynamic magnetic field monitoring AP Aitken, D Giese, C Tsoumpas, P Schleyer, S Kozerke, C Prieto, ... Medical physics 41 (1), 012302, 2014 | 56 | 2014 |
Accuracy of 4D Flow Measurement of Cerebrospinal Fluid Dynamics in the Cervical Spine: An In Vitro Verification Against Numerical Simulation S Heidari Pahlavian, AC Bunck, S Thyagaraj, D Giese, F Loth, ... Annals of biomedical engineering 44, 3202-3214, 2016 | 52 | 2016 |
Patient-specific bicuspid aortic valve biomechanics: a magnetic resonance imaging integrated fluid–structure interaction approach M Emendi, F Sturla, RP Ghosh, M Bianchi, F Piatti, FR Pluchinotta, ... Annals of biomedical engineering 49, 627-641, 2021 | 46 | 2021 |
Characterization and correction of eddy-current artifacts in unipolar and bipolar diffusion sequences using magnetic field monitoring RW Chan, C Von Deuster, D Giese, CT Stoeck, J Harmer, AP Aitken, ... Journal of Magnetic Resonance 244, 74-84, 2014 | 45 | 2014 |
A sensitivity analysis on 3D velocity reconstruction from multiple registered echo Doppler views A Gomez, K Pushparajah, JM Simpson, D Giese, T Schaeffter, G Penney Medical image analysis 17 (6), 616-631, 2013 | 37 | 2013 |
Self‐gated golden‐angle spiral 4D flow MRI R Bastkowski, K Weiss, D Maintz, D Giese Magnetic resonance in medicine 80 (3), 904-913, 2018 | 31 | 2018 |
Respiratory motion corrected 4D flow using golden radial phase encoding C Kolbitsch, R Bastkowski, T Schäffter, C Prieto Vasquez, K Weiss, ... Magnetic Resonance in Medicine 83 (2), 635-644, 2020 | 27 | 2020 |