Modern analytical supercritical fluid chromatography using columns packed with sub-2 μm particles: a tutorial L Nováková, AGG Perrenoud, I Francois, C West, E Lesellier, D Guillarme Analytica chimica acta 824, 18-35, 2014 | 327 | 2014 |
Comparison of ultra-high performance supercritical fluid chromatography and ultra-high performance liquid chromatography for the analysis of pharmaceutical compounds AGG Perrenoud, JL Veuthey, D Guillarme Journal of Chromatography A 1266, 158-167, 2012 | 250 | 2012 |
Analysis of basic compounds by supercritical fluid chromatography: Attempts to improve peak shape and maintain mass spectrometry compatibility AGG Perrenoud, J Boccard, JL Veuthey, D Guillarme Journal of Chromatography A 1262, 205-213, 2012 | 149 | 2012 |
Coupling state-of-the-art supercritical fluid chromatography and mass spectrometry: from hyphenation interface optimization to high-sensitivity analysis of pharmaceutical compounds AGG Perrenoud, JL Veuthey, D Guillarme Journal of Chromatography A 1339, 174-184, 2014 | 138 | 2014 |
Ultra high performance supercritical fluid chromatography coupled with tandem mass spectrometry for screening of doping agents. II: analysis of biological samples L Nováková, M Rentsch, AGG Perrenoud, R Nicoli, M Saugy, JL Veuthey, ... Analytica chimica acta 853, 647-659, 2015 | 136 | 2015 |
The use of columns packed with sub-2 µm particles in supercritical fluid chromatography AGG Perrenoud, JL Veuthey, D Guillarme TrAC Trends in Analytical Chemistry 63, 44-54, 2014 | 104 | 2014 |
Maximizing kinetic performance in supercritical fluid chromatography using state-of-the-art instruments AGG Perrenoud, C Hamman, M Goel, JL Veuthey, D Guillarme, S Fekete Journal of Chromatography A 1314, 288-297, 2013 | 96 | 2013 |
A systematic investigation of sample diluents in modern supercritical fluid chromatography V Desfontaine, A Tarafder, J Hill, J Fairchild, AGG Perrenoud, JL Veuthey, ... Journal of Chromatography A 1511, 122-131, 2017 | 87 | 2017 |
Evaluation of various chromatographic approaches for the retention of hydrophilic compounds and MS compatibility A Periat, A Grand‐Guillaume Perrenoud, D Guillarme Journal of separation science 36 (19), 3141-3151, 2013 | 69 | 2013 |
Evaluation and comparison of various separation techniques for the analysis of closely-related compounds of pharmaceutical interest C Gourmel, AGG Perrenoud, L Waller, E Reginato, J Verne, B Dulery, ... Journal of Chromatography A 1282, 172-177, 2013 | 69 | 2013 |
Ultra-high performance supercritical fluid chromatography coupled with quadrupole-time-of-flight mass spectrometry as a performing tool for bioactive analysis AGG Perrenoud, D Guillarme, J Boccard, JL Veuthey, D Barron, S Moco Journal of Chromatography A 1450, 101-111, 2016 | 67 | 2016 |
First inter-laboratory study of a Supercritical Fluid Chromatography method for the determination of pharmaceutical impurities A Dispas, R Marini, V Desfontaine, JL Veuthey, D Kotoni, LG Losacco, ... Journal of pharmaceutical and biomedical analysis 161, 414-424, 2018 | 64 | 2018 |
Quantitative profiling of endogenous fat-soluble vitamins and carotenoids in human plasma using an improved UHPSFC-ESI-MS interface F Petruzziello, A Grand-Guillaume Perrenoud, A Thorimbert, M Fogwill, ... Analytical chemistry 89 (14), 7615-7622, 2017 | 57 | 2017 |
Comparison of liquid chromatography and supercritical fluid chromatography coupled to compact single quadrupole mass spectrometer for targeted in vitro metabolism assay D Spaggiari, F Mehl, V Desfontaine, AGG Perrenoud, S Fekete, S Rudaz, ... Journal of Chromatography A 1371, 244-256, 2014 | 57 | 2014 |
Supercritical fluid chromatography in natural product analysis–An update NG Eisath, S Sturm, H Stuppner Planta medica 84 (06/07), 361-371, 2018 | 55 | 2018 |
Evaluation of stationary phases packed with superficially porous particles for the analysis of pharmaceutical compounds using supercritical fluid chromatography AGG Perrenoud, WP Farrell, CM Aurigemma, NC Aurigemma, S Fekete, ... Journal of Chromatography A 1360, 275-287, 2014 | 54 | 2014 |
Optimized selection of liquid chromatography conditions for wide range analysis of natural compounds A Periat, D Guillarme, JL Veuthey, J Boccard, S Moco, D Barron, ... Journal of Chromatography A 1504, 91-104, 2017 | 31 | 2017 |
Maximizing kinetic performance in supercritical fluid chromatography using state-of-the-art instruments A Grand-Guillaume Perrenoud, C Hamman, M Goel, JL Veuthey, ... Journal of Chromatography A 1314 (1), 288-297, 2013 | 28 | 2013 |
Interlaboratory study of a supercritical fluid chromatography method for the determination of pharmaceutical impurities: evaluation of multi-systems reproducibility A Dispas, A Clarke, AGG Perrenoud, LG Losacco, JL Veuthey, Q Gros, ... Journal of pharmaceutical and biomedical analysis 203, 114206, 2021 | 24 | 2021 |
Evolution and current trends in liquid and supercritical fluid chromatography S Fekete, A Grand-Guillaume Perrenoud, D Guillarme Current Chromatography 1 (1), 15-40, 2014 | 24 | 2014 |