Follow
Lukmanda Evan Lubis
Lukmanda Evan Lubis
Department of Physics, Faculty of Mathematics and Natural Sciences, Universitas Indonesia
Verified email at sci.ui.ac.id - Homepage
Title
Cited by
Cited by
Year
Brief histories of medical physics in Asia-Oceania
WH Round, S Jafari, T Kron, HA Azhari, S Chhom, Y Hu, GF Mauldon, ...
Australasian physical & engineering sciences in medicine 38, 381-398, 2015
142015
Task-based phantom evaluation of cardiac catheterization imaging modes
LE Lubis, LA Craig, H Bosmans, DS Soejoko
Physica Medica 46, 114-123, 2018
132018
Optimization of dose and image quality of paediatric cardiac catheterization procedure
LE Lubis, I Bayuadi, SA Pawiro, KH Ng, H Bosmans, DS Soejoko
Physica Medica 31 (7), 659-668, 2015
132015
Fast and accurate detection of Covid-19-related pneumonia from chest X-ray images with novel deep learning model
MM Ramadhan, A Faza, LE Lubis, RE Yunus, T Salamah, D Handayani, ...
arXiv preprint arXiv:2005.04562, 2020
112020
Optimization of digital radiography system using in-house phantom: Preliminary study
I Hariyati, ADF Hani, LA Craig, I Lestariningsih, LE Lubis, DS Soejoko
Journal of Physics: Conference Series 1248 (1), 012021, 2019
92019
Construction and evaluation of a multipurpose performance check phantom for computed tomography
LE Lubis, I Hariyati, D Ryangga, IAS Mu'minah, T Mart, DS Soejoko
Atom Indonesia 46 (2), 69-75, 2020
72020
Radiation dose from dental radiography in Indonesia: A five-year survey
LE Lubis, I Bayuadi, YA Bayhaqi, F Ardiansyah, AR Setiadi, RD Sugandi, ...
Radiation Protection Dosimetry 183 (3), 342-347, 2019
72019
Parameter-based estimation of CT dose index and image quality using an in-house android™-based software
S Mubarok, LE Lubis, SA Pawiro
Journal of Physics: Conference Series 694 (1), 012037, 2016
72016
Measurement of computed tomography dose profile with pitch variation using Gafchromic XR-QA2 and thermoluminescence dosimeter (TLD)
S Purwaningsih, LE Lubis, SA Pawiro, DS Soejoko
Journal of Physics: Conference Series 694 (1), 012046, 2016
62016
Novel phantom for performance evaluation of contrast-enhanced 3D rotational angiography
LE Lubis, RA Basith, I Hariyati, D Ryangga, T Mart, H Bosmans, ...
Physica Medica 90, 91-98, 2021
52021
Optimization of retinal blood vessel segmentation based on Gabor filters and particle swarm optimization
A Fauzi, LE Lubis
Indonesian Journal of Electrical Engineering and Computer Science 29 (3 …, 2023
42023
Developing and implementing a multi-modality imaging optimization study in paediatric radiology: Experience and recommendations from an IAEA coordinated research project
H Delis, P Homolka, CL Chapple, PR Costa, E Attalla, LE Lubis, ...
Physica Medica 82, 255-265, 2021
42021
Professional Training Scheme to Answer National Demand Medical Physicists in Indonesia
SA Pawiro, LE Lubis, AN Oktavianto, M Mukhlisin, DS Soejoko
MEDICAL PHYSICS 8 (2), 2020
42020
Local dose survey on paediatric multi-detector CT: A preliminary result
LE Lubis, AF Jundi, A Susilo, A Evianti, DS Soejoko
World Congress on Medical Physics and Biomedical Engineering 2018: June 3-8 …, 2019
42019
Overseeing the Growth of Medical Physics: Indonesia Case
SA Pawiro, LE Lubis, AN Oktavianto, DS Soejoko
World Congress on Medical Physics and Biomedical Engineering 2018: June 3-8 …, 2019
42019
Measuring radiation dose to patients undergoing fluoroscopically-guided interventions
LE Lubis, MK Badawy
Journal of Physics: Conference Series 694 (1), 012049, 2016
42016
Medical physics in Indonesia: current status and plans
DS Soejoko, SA Pawiro, LE Lubis
World Congress on Medical Physics and Biomedical Engineering, June 7-12 …, 2015
32015
Optimisasi dosis dan kualitas citra pada radiologi diagnostik: langkah-langkah, tips, dan panduan praktis
LE Lubis, DS Soejoko
Journal of Medical Physics and Biophysics 7 (1), 22-31, 2020
22020
Effect of pitch on CT image quality based on SNR evaluation using in house phantom
I Lestariningsih, LE Lubis, DS Soejoko
Journal of Physics: Conference Series 1248 (1), 012027, 2019
22019
Computer aided diagnosis (cad) for mammography with Markov random field method with simulated annealing optimization
NLK Sari, P Prajitno, LE Lubis, DS Soejoko
Journal of Medical Physics and Biophysics 4 (1), 85-94, 2017
22017
The system can't perform the operation now. Try again later.
Articles 1–20