Follow
Juan P. Hidalgo
Title
Cited by
Cited by
Year
Effects of exposed cross laminated timber on compartment fire dynamics
RM Hadden, AI Bartlett, JP Hidalgo, S Santamaria, F Wiesner, LA Bisby, ...
Fire Safety Journal 91, 480-489, 2017
1282017
Description of small and large-scale cross laminated timber fire tests
R Emberley, CG Putynska, A Bolanos, A Lucherini, A Solarte, D Soriguer, ...
Fire Safety Journal 91, 327-335, 2017
862017
Structural capacity in fire of laminated timber elements in compartments with exposed timber surfaces
F Wiesner, LA Bisby, AI Bartlett, JP Hidalgo, S Santamaria, S Deeny, ...
Engineering Structures 179, 284-295, 2019
782019
The Malveira fire test: Full-scale demonstration of fire modes in open-plan compartments
JP Hidalgo, T Goode, V Gupta, A Cowlard, C Abecassis-Empis, J Maclean, ...
Fire Safety Journal 108, 102827, 2019
742019
Auto-extinction of engineered timber: Application to compartment fires with exposed timber surfaces
AI Bartlett, RM Hadden, JP Hidalgo, S Santamaria, F Wiesner, LA Bisby, ...
Fire Safety Journal 91, 407-413, 2017
722017
A Thin Skin Calorimeter (TSC) for quantifying irradiation during large-scale fire testing
JP Hidalgo, C Maluk, A Cowlard, C Abecassis-Empis, M Krajcovic, ...
International Journal of Thermal Sciences 112, 383-394, 2017
712017
An experimental study of full-scale open floor plan enclosure fires
JP Hidalgo, A Cowlard, C Abecassis-Empis, C Maluk, AH Majdalani, ...
Fire Safety Journal 89, 22-40, 2017
702017
Performance criteria for the fire safe use of thermal insulation in buildings
JP Hidalgo, S Welch, JL Torero
Construction and Building Materials 100, 285-297, 2015
632015
Fire dynamics in mass timber compartments
C Gorska, JP Hidalgo, JL Torero
Fire Safety Journal 120, 103098, 2021
542021
Fire performance of charring closed‐cell polymeric insulation materials: Polyisocyanurate and phenolic foam
JP Hidalgo, JL Torero, S Welch
Fire and Materials 42 (4), 358-373, 2018
442018
Performance-based methodology for the fire safe design of insulation materials in energy efficient buildings
JP Hidalgo-Medina
The University of Edinburgh, 2015
422015
Experimental characterisation of the fire behaviour of thermal insulation materials for a performance-based design methodology
JP Hidalgo, JL Torero, S Welch
Fire technology 53, 1201-1232, 2017
362017
Large-scale compartment fires to develop a self-extinction design framework for mass timber—Part 1: Literature review and methodology
H Xu, I Pope, V Gupta, J Cadena, J Carrascal, D Lange, MS McLaggan, ...
Fire Safety Journal 128, 103523, 2022
332022
Burning dynamics and in-depth flame spread of wood cribs in large compartment fires
V Gupta, JL Torero, JP Hidalgo
Combustion and flame 228, 42-56, 2021
322021
Ventilation effects on the thermal characteristics of fire spread modes in open-plan compartment fires
V Gupta, JP Hidalgo, A Cowlard, C Abecassis-Empis, AH Majdalani, ...
Fire Safety Journal 120, 103072, 2021
322021
A comparison of the conditions in a fire resistance furnace when testing combustible and non-combustible construction
D Lange, J Sjöström, J Schmid, D Brandon, J Hidalgo
Fire technology 56, 1621-1654, 2020
322020
A correction method for thermal disturbances induced by thermocouples in a low-conductivity charring material
I Pope, JP Hidalgo, JL Torero
Fire Safety Journal 120, 103077, 2021
312021
Thermal inertia as an integrative parameter for building performance
GM Soret, P Vacca, J Tignard, JP Hidalgo, C Maluk, M Aitchison, ...
Journal of Building Engineering 33, 101623, 2021
302021
Flammability trends for a comprehensive array of cladding materials
MS McLaggan, JP Hidalgo, J Carrascal, MT Heitzmann, AF Osorio, ...
Fire safety journal 120, 103133, 2021
272021
A simplified correction method for thermocouple disturbance errors in solids
I Pope, JP Hidalgo, RM Hadden, JL Torero
International Journal of Thermal Sciences 172, 107324, 2022
262022
The system can't perform the operation now. Try again later.
Articles 1–20