Follow
Amit Jain
Amit Jain
Imaging Scientist
Verified email at buffalo.edu
Title
Cited by
Cited by
Year
A theoretical and experimental evaluation of the microangiographic fluoroscope: A high‐resolution region‐of‐interest x‐ray imager
A Jain, DR Bednarek, C Ionita, S Rudin
Medical physics 38 (7), 4112-4126, 2011
482011
A theoretical and experimental evaluation of the microangiographic fluoroscope: A high‐resolution region‐of‐interest x‐ray imager
A Jain, DR Bednarek, C Ionita, S Rudin
Medical physics 38 (7), 4112-4126, 2011
482011
A theoretical and experimental evaluation of the microangiographic fluoroscope: A high‐resolution region‐of‐interest x‐ray imager
A Jain, DR Bednarek, C Ionita, S Rudin
Medical physics 38 (7), 4112-4126, 2011
482011
A theoretical and experimental evaluation of the microangiographic fluoroscope: A high-resolution region-of-interest x-ray imager
A Jain, DR Bednarek, C Ionita, S Rudin
Medical physics 38 (7), 4112-4126, 2011
482011
Accurate MTF measurement in digital radiography using noise response
A Kuhls-Gilcrist, A Jain, DR Bednarek, KR Hoffmann, S Rudin
Medical physics 37 (2), 724-735, 2010
472010
Use of the microangiographic fluoroscope for coiling of intracranial aneurysms
MJ Binning, D Orion, P Yashar, S Webb, CN Ionita, A Jain, S Rudin, ...
Neurosurgery 69 (5), 1131-1138, 2011
302011
The solid state x-ray image intensifier (SSXII): An EMCCD-based x-ray detector
A Kuhls-Gilcrist, G Yadava, V Patel, A Jain, DR Bednarek, S Rudin
Medical Imaging 2008: Physics of Medical Imaging 6913, 192-201, 2008
262008
The solid state x-ray image intensifier (SSXII): An EMCCD-based x-ray detector
A Kuhls-Gilcrist, G Yadava, V Patel, A Jain, DR Bednarek, S Rudin
Medical Imaging 2008: Physics of Medical Imaging 6913, 192-201, 2008
262008
Implementation of a high-sensitivity Micro-Angiographic Fluoroscope (HS-MAF) for in-vivo endovascular image guided interventions (EIGI) and region-of-interest computed …
CN Ionita, C Keleshis, V Patel, G Yadava, KR Hoffmann, DR Bednarek, ...
Medical Imaging 2008: Visualization, Image-Guided Procedures, and Modeling …, 2008
232008
Focal spot measurements using a digital flat panel detector
A Jain, A Panse, DR Bednarek, S Rudin
Medical Imaging 2014: Physics of Medical Imaging 9033, 1488-1493, 2014
202014
Progress in the development of a new angiography suite including the high resolution micro-angiographic fluoroscope (MAF): a control, acquisition, processing, and image display …
W Wang, CN Ionita, C Keleshis, A Kuhls-Gilcrist, A Jain, D Bednarek, ...
Medical Imaging 2010: Physics of Medical Imaging 7622, 1716-1725, 2010
202010
Limitations of anti-scatter grids when used with high resolution image detectors
V Singh, A Jain, DR Bednarek, S Rudin
Medical Imaging 2014: Physics of Medical Imaging 9033, 1618-1626, 2014
192014
Endovascular coil embolization of a very small ruptured aneurysm using a novel microangiographic technique
P Kan, P Yashar, CN Ionita, A Jain, S Rudin, EI Levy, AH Siddiqui
Journal of neurointerventional surgery 5 (2), e2-e2, 2013
192013
Scatter estimation and removal of anti-scatter grid-line artifacts from anthropomorphic head phantom images taken with a high resolution image detector
R Rana, A Jain, A Shankar, DR Bednarek, S Rudin
Medical Imaging 2016: Physics of Medical Imaging 9783, 1619-1628, 2016
182016
Experimental and theoretical performance analysis for a CMOS-based high resolution image detector
A Jain, DR Bednarek, S Rudin
Medical Imaging 2014: Physics of Medical Imaging 9033, 1057-1064, 2014
172014
Generalized two-dimensional (2D) linear system analysis metrics (GMTF, GDQE) for digital radiography systems including the effect of focal spot, magnification, scatter, and …
A Jain, AT Kuhls-Gilcrist, SK Gupta, DR Bednarek, S Rudin
Medical Imaging 2010: Physics of Medical Imaging 7622, 204-213, 2010
172010
Modification of the NEMA XR21-2000 cardiac phantom for testing of imaging systems used in endovascular image guided interventions
CN Ionita, A Dohatcu, A Jain, C Keleshis, KR Hoffmann, DR Bednarek, ...
Medical Imaging 2009: Physics of Medical Imaging 7258, 1474-1482, 2009
162009
Focal spot de-blurring
S Rudin, DR Bednarek, A Jain, J Manak
US Patent App. 10/019,795, 2018
15*2018
Micro-Computed tomography (CT) based assessment of dental regenerative therapy in the canine mandible model
P Khobragade, A Jain, SVS Nagesh, S Andreana, R Dziak, SK Sunkara, ...
Medical Imaging 2015: Biomedical Applications in Molecular, Structural, and …, 2015
152015
New head equivalent phantom for task and image performance evaluation representative for neurovascular procedures occurring in the Circle of Willis
CN Ionita, B Loughran, A Jain, SNS Vasan, DR Bednarek, E Levy, ...
Medical Imaging 2012: Physics of Medical Imaging 8313, 241-252, 2012
142012
The system can't perform the operation now. Try again later.
Articles 1–20