GREIT: a unified approach to 2D linear EIT reconstruction of lung images A Adler, JH Arnold, R Bayford, A Borsic, B Brown, P Dixon, TJC Faes, ... Physiological measurement 30 (6), S35, 2009 | 747 | 2009 |
Bioimpedance tomography (electrical impedance tomography) RH Bayford Annu. Rev. Biomed. Eng. 8 (1), 63-91, 2006 | 540 | 2006 |
Three-dimensional electrical impedance tomography of human brain activity T Tidswell, A Gibson, RH Bayford, DS Holder NeuroImage 13 (2), 283-294, 2001 | 256 | 2001 |
Electrical impedance tomography of human brain function using reconstruction algorithms based on the finite element method AP Bagshaw, AD Liston, RH Bayford, A Tizzard, AP Gibson, AT Tidswell, ... NeuroImage 20 (2), 752-764, 2003 | 224 | 2003 |
Whither lung EIT: where are we, where do we want to go and what do we need to get there? A Adler, MB Amato, JH Arnold, R Bayford, M Bodenstein, SH Böhm, ... Physiological measurement 33 (5), 679, 2012 | 213 | 2012 |
Multi-frequency electrical impedance tomography (EIT) of the adult human head: initial findings in brain tumours, arteriovenous malformations and chronic stroke, development of … A Romsauerova, A McEwan, L Horesh, R Yerworth, RH Bayford, ... Physiological measurement 27 (5), S147, 2006 | 172 | 2006 |
Use of anisotropic modelling in electrical impedance tomography; description of method and preliminary assessment of utility in imaging brain function in the adult human head JFPJ Abascal, SR Arridge, D Atkinson, R Horesh, L Fabrizi, M De Lucia, ... Neuroimage 43 (2), 258-268, 2008 | 150 | 2008 |
Design and calibration of a compact multi-frequency EIT system for acute stroke imaging A McEwan, A Romsauerova, R Yerworth, L Horesh, R Bayford, D Holder Physiological measurement 27 (5), S199, 2006 | 146 | 2006 |
Electrical impedance tomography spectroscopy (EITS) for human head imaging RJ Yerworth, RH Bayford, B Brown, P Milnes, M Conway, DS Holder Physiological measurement 24 (2), 477, 2003 | 114 | 2003 |
Generating accurate finite element meshes for the forward model of the human head in EIT A Tizzard, L Horesh, RJ Yerworth, DS Holder, RH Bayford Physiological measurement 26 (2), S251, 2005 | 112 | 2005 |
Detection of the tau protein in human serum by a sensitive four-electrode electrochemical biosensor SX Wang, D Acha, AJ Shah, F Hills, I Roitt, A Demosthenous, RH Bayford Biosensors and bioelectronics 92, 482-488, 2017 | 100 | 2017 |
A human–machine interface using electrical impedance tomography for hand prosthesis control Y Wu, D Jiang, X Liu, R Bayford, A Demosthenous IEEE transactions on biomedical circuits and systems 12 (6), 1322-1333, 2018 | 96 | 2018 |
Factors limiting the application of electrical impedance tomography for identification of regional conductivity changes using scalp electrodes during epileptic seizures in humans L Fabrizi, M Sparkes, L Horesh, JFPJ Abascal, A McEwan, RH Bayford, ... Physiological measurement 27 (5), S163, 2006 | 95 | 2006 |
Bioimpedance imaging: an overview of potential clinical applications R Bayford, A Tizzard Analyst 137 (20), 4635-4643, 2012 | 93 | 2012 |
Emerging applications of nanotechnology for diagnosis and therapy of disease: a review R Bayford, T Rademacher, I Roitt, SX Wang Physiological measurement 38 (8), R183, 2017 | 92 | 2017 |
Design and performance of the UCLH Mark 1b 64 channel electrical impedance tomography (EIT) system, optimized for imaging brain function RJ Yerworth, RH Bayford, G Cusick, M Conway, DS Holder Physiological measurement 23 (1), 149, 2002 | 88 | 2002 |
Electrical impedance tomography of human brain activity with a two-dimensional ring of scalp electrodes AT Tidswell, A Gibson, RH Bayford, DS Holder Physiological measurement 22 (1), 167, 2001 | 85 | 2001 |
A high frame rate wearable EIT system using active electrode ASICs for lung respiration and heart rate monitoring Y Wu, D Jiang, A Bardill, S De Gelidi, R Bayford, A Demosthenous IEEE Transactions on Circuits and Systems I: Regular Papers 65 (11), 3810-3820, 2018 | 82 | 2018 |
Validation of a 3D reconstruction algorithm for EIT of human brain function in a realistic head-shaped tank AT Tidswell, A Gibson, RH Bayford, DS Holder Physiological measurement 22 (1), 177, 2001 | 79 | 2001 |
The influence of ligand organization on the rate of uptake of gold nanoparticles by colorectal cancer cells T Lund, MF Callaghan, P Williams, M Turmaine, C Bachmann, ... Biomaterials 32 (36), 9776-9784, 2011 | 76 | 2011 |